# F-Gas (Refrigerant Log)

> **Portal:** Admin Portal · **Section:** Modules & Navigation · **Updated:** 2026-10-26
> **Menu:** F-Gas
> **Canonical URL:** https://docs.field-ascend.com/admin-portal/nav/fgas

## What This Area Is For

The **F-Gas** menu opens the **Refrigerant Log** — a central place to review refrigerant-related activity across your account, support compliance reporting, and monitor **leak-check due dates** for equipment that is in scope for that tracking.

Day-to-day refrigerant entries (charges, top-ups, recoveries, leak checks, and similar) are usually captured **on the job** by engineers in the mobile app. This admin page is mainly for **oversight, filtering, exports, and leak-check compliance**, not for typing every field visit by hand.

If you do not see **F-Gas** in the main navigation, the refrigerant module is not enabled for your account. It is turned on from **Equipment setup**, on the **F-Gas / Refrigerant** tab.

## What You'll See On This Page

### Page header

- Title: **Refrigerant Log**
- Short subtitle explaining F-Gas compliance tracking across equipment
- **Export CSV** — downloads a spreadsheet of the **currently filtered** log rows (same columns as the on-screen table, suitable for auditors or spreadsheets)

### Leak-check compliance summary (four tiles)

Four large **clickable** summary tiles appear near the top:

1. **Overdue** — equipment whose next leak check date is **before today**
2. **Due within 30 days** — next check due in the next 30 days
3. **Never checked** — equipment that needs a first scheduled check (shown in the drill-down list as **Never Checked (Requires Check)**)
4. **Compliant** — next check due **more than 30 days** ahead

Each tile shows a count and **Click to view**. Selecting a tile opens a **filtered equipment list** below the tiles (not the main refrigerant log table). That list includes customer, site, refrigerant, charge, CO2 equivalent, last check, next due, and an action to open the equipment record.

When some leak checks could not be carried out, a chip **Unable to test** shows how many. Those units stay due.

Use **Clear filter** (or the link back to the full log) to leave the compliance drill-down and return to the normal log view.

### Filter panel (main log)

Use **Filter** to apply criteria; use **Clear** to reset filters.

Visible filters for the **main refrigerant log table**:

- **Customer**
- **Gas type** (refrigerant type)
- **Action** — Initial Charge, Top Up, Recovery, Leak Check, Decommission
- **Engineer**
- **Date from** / **Date to** (calendar inputs; interpreted in your account **timezone** for display and filtering)

### Totals bar (under the filters)

Summary chips for the **filtered** result set, including:

- how many **entries** are shown
- **Charged** and **Recovered** mass (kg)
- **Net** (charged minus recovered)
- count of **Leak checks**

### Main results table

Columns typically include:

- **Date** (when the action was recorded)
- **Customer**, **Site**, **Equipment** (equipment name is a link to the equipment editor)
- **Action** (colour-coded). For **Leak check**, a small **PASS** / **FAIL** style badge may appear when a result was recorded
- **Gas**, **Qty (kg)**, **CO2e (t)**, **Running (kg)** (running charge after the entry)
- **Engineer**, **Job** (job number links to the job when a job was linked)
- **Notes** (truncated in the grid)

If there are many rows, the page may show a message that only the **first 500** entries are listed and suggest **narrowing with filters**.

## What You Can Do Here

- See **who did what**, on **which equipment**, for **which customer/site**, and on **which job** (when linked)
- **Slice the log** by customer, refrigerant, action type, engineer, and date range
- **Export** the current view to CSV for compliance files or analysis
- Use the **compliance tiles** to find equipment that is overdue, due soon, never checked, or compliant — then jump into **equipment** to update refrigerant details or plan work
- Open **equipment** or **jobs** directly from links in the table

## Common Tasks

### Find all refrigerant work for one customer

1. Choose the **Customer** filter.
2. Select **Filter**.
3. Optionally narrow further by **Date from** / **Date to** or **Action**.

### Review leak checks performed in a period

1. Set **Action** to **Leak check**.
2. Set **Date from** and **Date to** to your reporting window.
3. Select **Filter**.
4. Use **Export CSV** if you need a file.

### See which equipment needs attention for leak checks

1. Click **Overdue**, **Due within 30 days**, or **Never checked** on the summary tiles.
2. Review the equipment list.
3. Use **View F-Gas** (or the equipment name) to open the equipment record and work through scheduling or recording checks on site.

### Prepare evidence for an audit

1. Apply filters that match the audit scope (customer, date range, gas type, etc.).
2. Select **Export CSV**.
3. Keep the export with your other job and equipment evidence.

## Cylinders and disposals (only when "Track cylinders" is ticked)

When your company ticks **Track cylinders** (Equipment setup → F-Gas / Refrigerant → Force Rules), each charge, top-up, recovery and decommission can record **which cylinder** the gas came from or went into, and the F-Gas pages gain three tabs: **Log**, **Cylinders** and **Disposals**. With the box unticked none of this appears.

- **Log** (this page) gains a **Cylinder** column, a **Cylinder** filter (type a number, or `none` to find recoveries with no cylinder number), and the **Export CSV** gains a **Cylinder** column at the end. A cylinder number in the column opens that cylinder; under a recovery whose cylinder has since been sent for disposal it adds **→ sent** *date* **to** *facility*. People who can edit F-Gas records can tick entries — a bar appears at the bottom of the screen with a **Cylinder number** box, **Set cylinder**, **Remove number** and **Cancel** — or use the pencil next to an entry, to add, correct or clear a number afterwards. The original notes are kept and a line is added saying who changed it and when. Leak checks and corrections never carry a cylinder; ticked entries like that, or ones already on that number, are left as they were and the message says how many.
- **Cylinders** lists every cylinder your team has named. A cylinder is added automatically the first time an engineer enters its number; you can also **Add cylinder** yourself. It shows the gas, whether it is a **supply** cylinder (gas taken from it) or a **recovery** cylinder (gas put into it), what it **holds**, its last movement and where it is. What it holds is worked out from the entries and disposals, so it needs a **start quantity** (a new recovery cylinder starts empty). Open a cylinder to see every movement, its disposals, and to **Track as a tool** — that creates a tool in Tools so it gets a holder (store, van or person), a QR label, test dates and certificates. **Retire** hides a cylinder from engineers without deleting its history.
- **Disposals** records where recovered gas went: the date, the route (**Reclaim**, **Recycle**, **Destroy**, **Return to supplier**, **Other**), the facility and its certificate or permit number, the waste carrier and registration, the consignment / transfer note number, and the quantity per cylinder. Select cylinders on the **Cylinders** tab and press **Send for disposal**, or start one from the **Disposals** tab. After saving you can attach the note. Deleting a disposal needs the word **DELETE** typed in.
- Chips above the filters point to anything worth tidying: recoveries with no cylinder number (opens the log filtered to them), cylinders that may hold more than one gas, and entries not yet linked to the register (both open **Cylinders**). To stop a recovery being saved without a number, tick **Require a cylinder number on every recovery**, which appears under **Track cylinders** once that is ticked — the web and app forms then refuse a recovery without one, with or without signal. An entry already saved on a phone is never lost when it syncs (one from an older app version can arrive without a number), so the chip still catches those.
- The **F-Gas logbook** template can show a **Cylinder** column and a **Recovery and disposal** section (both off until ticked in the logbook template editor). The job sheet and PPM F-Gas tables can add a **Cylinder** column in the template builder.

- The three tabs sit on their own row under the page title on all three pages.
- **A new cylinder's start quantity**: when someone types a cylinder number the register has not seen, the entry form (web and app) asks **What is in it now?** — what was in the cylinder before that entry (a full new cylinder is its fill weight). It is optional; it is applied only when the register row is created, so a figure the office has already entered is never overwritten, and if two people name the same new cylinder the first start quantity stands.
- **From the app**: engineers with the **Cylinders** tile can add a cylinder (with its start quantity) and, when their staff record has **Can record F-Gas disposals (app)**, record a disposal at the facility with a photo of the completed transfer note. Those disposals appear on **Disposals** with a phone icon and "Recorded by *name* (engineer, from the app)"; the photo arrives under **Paperwork** on the sync after the record. Editing or deleting a disposal stays an office action.

A cylinder number is not a legal requirement in itself; it is the simplest way to show which cylinder recovered gas went into and where that cylinder went.

## Important Options

These are configured outside this page but change what engineers must do and what appears elsewhere:

- **Equipment setup → F-Gas / Refrigerant** — enables the module, refrigerant types, which equipment types are in scope, and options such as forcing refrigerant logging or leak checks on the app for qualifying equipment.
- **Dashboard** — optional F-Gas tiles (e.g. overdue / due soon) can be added when your team enables dashboard visibility for F-Gas from that same setup area.

## Common Mistakes

- **Expecting to enter every log line here** — most entries originate from **engineers on jobs** (and equipment). This page is for visibility and export, not the primary data-entry screen.
- **Confusing the compliance list with the log** — clicking a compliance tile shows **equipment due-status**, not the chronological refrigerant log. Use **Clear filter** to get back to the full log table.
- **Missing the F-Gas menu** — the menu item is hidden until the module is enabled in **Equipment setup**.
- **Very wide date ranges** — the table is capped at 500 rows; tighten filters if you need a complete picture in one view.

## Related Areas

- **Equipment** — refrigerant type, charge, CO2 equivalent, last/next leak check; section labelled for F-Gas on the equipment editor.
- **Jobs** — where engineers attach refrigerant activity to live work; job numbers in the log link back here.
- **Engineers app** — where compliant teams usually record charges, top-ups, recoveries, and leak checks against equipment on the job.
- **Equipment setup → F-Gas / Refrigerant** — module switch, refrigerant catalogue, equipment-type scope, and enforcement options for the app.