What This Area Is For
Lone Working is an office-side safety monitoring screen for field engineers. It brings together live status, recent activity, map positions, and escalation-style alerts so supervisors can see who appears active, who may need a check-in, and who has raised an emergency or not responded to a siren prompt.
The product treats this as a supporting tool only (not a certified lone-worker alarm service or a substitute for your own risk assessments and emergency procedures). The page explains that clearly in settings and may ask you to accept terms before you can use the feature.
What You'll See On This Page
Top of the page
- Title Lone Working Safety with short explanatory text about real-time monitoring and multiple activity sources.
- TV mode — fullscreen layout aimed at a wall screen or reception display (large stats, map, and engineer list; simplified chrome).
- A LIVE or DISABLED pill that reflects whether monitoring is turned on in the Settings tab.
- A small last updated time that refreshes when the dashboard reloads its data (the live view also auto-refreshes on a fixed interval).
Prerequisites banner (when relevant)
If key mobile options are not set the way this feature expects, you may see a yellow Prerequisites Not Met panel. It tells you what is wrong in plain language (for example timing set to manual entry instead of live button flow, GPS collection turned off, or background upload service disabled) and links you to App Settings to fix it. Lone Working still loads, but location and “freshness” of signals can be weaker until those options are corrected.
Three tabs
- Live Dashboard — map, headline counts, and engineer list (this is what TV mode emphasises).
- Settings — enable/disable monitoring, thresholds, panic and siren behaviour, contacts, and notification toggles.
- Alert History — filtered history of alerts, emergencies, check-ins, and response-style summaries for a chosen period.
Live Dashboard tab
- Disabled notice (blue information panel) when monitoring is off, pointing you to Settings to enable it.
- Five stat tiles: Active, Warning, Alert, Off Duty, and Total engineers. Colours match severity (green / amber / red / purple / blue).
- Live Locations map with a Refresh control. Engineers with a usable position appear as circular markers; clicking a marker shows a short summary (name, status, time since last activity, current job number if known).
- Engineers panel on the right (or reorganised in TV mode): rows sorted by urgency (most serious first). Each row shows name, optional “moving” indicator, current job reference or “no active job”, last activity label, “time ago” text, and a status badge (for example Active, Warning, Alert, Off Duty, Holiday, Absent, or emergency-style labels when applicable).
- Rows may flash or highlight when they need attention. If an engineer has an active emergency state, a Mark Safe / Resolve style action can appear on that row (with confirmation and optional notes when you clear it).
- Clicking a row centres the map on that engineer when coordinates exist and opens the map popup.
- When the number of engineers in an alert-style state increases, the browser may play a short alert sound (browser autoplay rules can sometimes block audio until you have interacted with the page once).
Settings tab
- Enable Lone Working Monitoring checkbox, plus explanatory text that the system watches consolidated activity from many sources when enabled.
- A prominent legal / safety disclaimer: supplementary tool only, not a certified safety system, your organisation remains responsible for compliance; link to full terms (Section 8A).
- Alert thresholds — two numbers in minutes:
- Warning — after this long without qualifying activity, the engineer shows as warning (amber).
- Alert — after this longer period (and subject to movement logic shown on the dashboard), the engineer shows as alert (red) and supervisor escalation paths can apply.
- Panic button timings — how long the engineer must hold the in-app panic control, how long they have to cancel before send, and how long they can cancel after send.
- Siren alert — Siren Timeout (seconds) is how long a siren prompt can run before it is treated as “no response”. The Check-in Interval (minutes) box beside it is saved but does not send prompts today (see Important Options).
- Escalation contacts — comma-separated supervisor email addresses and supervisor phone numbers (mobile numbers, texted when SMS is ticked below).
- Notification methods — tick boxes for email and SMS, separately for alerts to engineers and alerts to supervisors. SMS (uses SMS credits) texts the engineer's own mobile when a safety alert fires (reaches a phone whose app is closed), and texts every supervisor phone number on escalation, panic and no-response — one credit per text, per number. SMS needs texting enabled with credits under Setup → SMS Setup; sent texts appear on Setup → Sent Texts. A note explains that siren-style prompts still go to the engineer’s mobile app via push notification regardless.
- Save Settings at the bottom.
Alert History tab
- Date range selector (for example last 7 / 30 / 90 days) and event type filter (all events, alerts only, emergencies only, check-ins only).
- Refresh button.
- Four summary tiles: Emergencies, Alerts triggered, Check-ins, and Average response time (when calculable).
- Scrollable event list with icons, engineer name, description, relative time, Resolved or Active badges where relevant, and sometimes a map shortcut when a location was recorded.
Terms gate (first use)
If your organisation has not yet accepted the current Lone Working terms, a full-screen modal blocks the page:
- Scrollable text covering limitations (not a certified ARC, no guarantee of delivery, possible delays if the app is offline, and similar).
- You must scroll to the bottom, tick I have read…, then Accept & Continue.
What You Can Do Here
- Turn Lone Working monitoring on or off and tune how quickly warnings and alerts appear.
- Watch a live map and list of engineers during the working day.
- Run TV mode on a dedicated screen (landscape or portrait layout, auto-scrolling list, exit control).
- Resolve an emergency state from the list when you have confirmed the engineer is safe.
- Review historical safety events and spot patterns (frequent no-response, long gaps, etc.).
- See prerequisite hints and jump to App Settings to improve GPS, timing mode, or background sync behaviour.
Common Tasks
Turn monitoring on for the first time
- Open Lone Working → Settings.
- Read the disclaimer and ensure your organisation is comfortable with the limitations (see Terms if needed).
- Tick Enable Lone Working Monitoring.
- Set warning and alert minutes to match your internal lone-worker policy (start conservative if unsure).
- Enter at least one supervisor email if you want email escalation.
- Choose which email toggles should be on for engineers vs supervisors.
- Select Save Settings.
- Return to Live Dashboard and confirm the LIVE pill appears.
Fix “prerequisites not met” warnings
- Read each bullet in the yellow banner (it names the exact product option that is off or mismatched).
- Open App Settings from the link in the banner.
- Switch timing to the live button-based flow if prompted, turn GPS required on if you need reliable positions, and enable background sync if engineers often work with poor connectivity so queued events still reach the server.
- Return to Lone Working and refresh; the banner should clear when the combination is acceptable.
Use TV mode in the office
- From Live Dashboard, select TV mode (the browser may ask for fullscreen permission).
- Use the floating controls to pick Landscape or Portrait depending on your display.
- Let the list auto-scroll, or hover to pause scrolling and read a specific engineer.
- Use Exit (or leave fullscreen) to return to the normal admin layout.
- For a wall screen that comes back by itself after a restart, open the page with
?tv=1on the address (a Chrome--kioskshortcut in the PC's Startup folder works well). Started that way, a stray Esc does not drop the layout — only Exit does. The page keeps refreshing every 30 seconds, asks the browser to keep the screen awake, reloads itself once a night, and if the login on that PC expires it shows Signed out and reconnects by itself when Remember me was ticked at sign-in.
Respond when an engineer is red or flashing
- Check the Engineers list (sorted by urgency) and the map popup for context (last activity type, job number, movement).
- Contact the engineer by your normal operational means (phone, radio, site contact).
- If they had triggered a panic or similar emergency state and you have confirmed they are safe, use Mark Safe / Resolve on their row, confirm, and optionally add a short note for the audit trail.
Investigate past incidents
- Open the Alert History tab.
- Choose a date range and narrow type if you only want emergencies or check-ins.
- Select Refresh and read down the event list; open the map link on an event when you need the rough location that was captured.
Important Options
- Enable / disable is organisation-wide: when disabled, the dashboard explains that monitoring is off and counts may stay static or empty.
- Warning vs alert minutes directly change how quickly amber and red states appear; they should align with how often engineers legitimately pause without touching the app.
- Panic and siren timings change how easy it is to trigger or cancel a distress signal accidentally vs how long supervisors wait before escalation.
- Check-in Interval (minutes) is saved but does not send any prompts today: the app never asks engineers to check in on a timer. What raises the siren on an engineer's phone is the Alert Threshold. When an engineer has had no app activity for that many minutes, the siren comes up, and the supervisors are told if it is not answered. To be told when someone has gone quiet for an hour or two, set the Alert Threshold to 60 or 120.
- Who is watched: monitoring is organisation-wide. There is no setting to switch it on for one job, job category or engineer only. An engineer is watched from their first Start Travel of the day until they finish their journey home, whichever job they are on. With typed times (manual time entry) the system cannot tell that an engineer has started work, so nobody is watched. The Prerequisites Not Met panel says so.
- Supervisor emails are the written escalation path; supervisor phone numbers are texted on escalation, panic and no-response when SMS is ticked under Alerts to Supervisors (uses SMS credits).
- TV mode hides normal navigation — it is meant for a trusted display, not everyday configuration work.
Common Mistakes
- Treating the dashboard as a guaranteed safety system — it depends on phones, connectivity, GPS, permissions, and user behaviour. Your procedures and training still come first.
- Leaving timing on manual entry and expecting continuous GPS “pings” — the prerequisite banner exists because manual mode does not produce the same live trace as button-based timing.
- Expecting instant updates when an engineer’s app is backgrounded or offline — the terms modal and on-page messaging describe delays; Background Sync mitigates but does not remove offline gaps.
- Enabling alerts but not filling supervisor emails — engineers may get app pushes while office staff receive nothing by email.
- Forgetting to place a wall display browser in fullscreen / kiosk — normal browser tabs can still show unrelated sites; use TV mode or a dedicated profile.
- Assuming deleting an engineer row clears a real-world emergency — always follow your organisation’s escalation policy; the Resolve action is an administrative confirmation inside the product after you have verified safety.
Related Areas
App Settings— GPS, timing mode, background sync, and other mobile behaviour that feeds this dashboard.Jobs— engineers often show a current job number on the list when one is active.Staff/ engineer profile editing — day-to-day permissions and mobile behaviour for individuals.- Terms of Service — Section 8A for the full contractual wording referenced from this page.