What This Area Is For
Equipment Setup is where you define how equipment is classified and captured across your account. You set up the types engineers choose from, optional extra fields on equipment records, status labels and colours, F-Gas / refrigerant behaviour if you use compliance tracking, and who is allowed to add or create equipment in the office and on site.
Changes here affect equipment lists on sites, job workflows, PPM matching by type, the Equipment list’s Required, not covered PPM filter, and (when enabled) F-Gas dashboards and customer-facing equipment pages.
What You'll See On This Page
The page opens with a horizontal tab bar. Each tab is a separate configuration area:
- Equipment Types — the list of type names (for example lift, boiler, AHU) used when recording equipment. Each type can also be marked Requires PPM, with an optional PPM Interval (months) for guidance.
- Custom Fields — optional extra questions on equipment beyond the standard identity fields. Each field can apply to all equipment or be scoped to specific equipment types (so engineers only see refrigerant questions on AC/refrigeration kit, lift questions on lifts, and so on).
- Statuses — labels such as operational or out of service, with colours and an optional dashboard flag.
- F-Gas / Refrigerant — master switch for the F-Gas module, which equipment types get refrigerant tracking, rules and leak-check timing, default and custom refrigerant lists, and a link to customise the F-Gas logbook PDF. Force Refrigerant Log on Jobs blocks completion when refrigerant equipment on the job has no gas log. Only force on these job categories (shown while that is on) limits the block to the categories you tick; leave them all unticked to force it on every category. An engineer who cannot test a unit records Unable to test with the reason — the job can close, and the unit stays due.
- Permissions — account-wide master switches for whether admins and engineers may add existing equipment to jobs or create brand-new equipment records.
- Asset Registers — reusable registers and reports: which columns (your custom fields, test results from a checksheet, open defects), how it prints (Table or Report with one card per asset, a cover, a summary, sign-off lines and attached PDFs), optional pin to a customer, optional customer-portal download. The list shows each register's Columns, Prints as (Table, Report or Report + pages), Pinned Customer and Portal, with CSV, PDF, Edit and Delete. Run them from Equipment, Reports, a customer or site (Reports tab), or this list.
- Reference Numbers — Automatic Reference Numbers for new Sites and Equipment (all types): a Prefix (for example ST or EQ-), how many Digits, and an optional Next number (blank = carry on). Next reference shows what the next one will be. Under Equipment Types With Their Own Numbers a type can have its own prefix (for example Boilers → BLR) and counts on its own; a type without one uses the equipment prefix. The number is given only when nobody types a reference — in the office, the engineers app, imports and Bulk Upload — and a typed reference is always kept. Leave a prefix blank to switch that numbering off. A number already used with the same prefix is never handed out again, even if you set Next number lower. Click Save Reference Numbers.
Most changes save immediately in the background (small confirmation messages appear). The F-Gas and Permissions tabs have explicit Save buttons for their settings.
You can bookmark or share a specific tab from the address bar after you open it.
Standard equipment fields (not on the Custom Fields tab)
Every account has built-in fields for Description, Equipment Ref, Make, Model, Serial No, Location, and Type. The Type dropdown’s options are exactly what you maintain under Equipment Types. You cannot remove these core fields from the tab; you extend the form using Custom Fields.
Standard lists for built-in fields (Make / Model / Location / Description)
On the Custom Fields tab, below the site-page columns panel, Standard lists for built-in fields lets you turn Make, Model, Location or Description into a managed list — for every equipment type at once (All types) or a different list per type (for example one Make list for Valves and another for Meters). Serial No and Equipment Ref stay free text.
For each field and type you choose a mode:
- Off (the default) — a free text box, exactly as before.
- Suggest — still a text box, but the list appears as autocomplete. Anything can be typed.
- List only — a dropdown of the list. Tick Other… (recommended) so an engineer can still type a make you haven't listed.
Whatever the mode, anything typed that matches a list entry — ignoring capitals, spaces and punctuation — is saved with the list's spelling. Typing "cla val" on site stores "Cla-Val". This applies in the office, in the engineer and admin apps, on PPM checksheets, on certificates that write back to the asset, and on bulk imports. Nothing is ever rejected: a value not on the list is kept exactly as typed.
The list itself has add / rename / reorder / delete. Rename updates every equipment record linked to that entry. Delete keeps the text on existing records — they simply stop being linked to the list.
A type with its own list overrides All types; a type with nothing configured inherits All types (the panel tells you which applies).
What You Can Do Here
- Add, rename, and remove equipment types, subject to use on real equipment, PPM checksheets or certificate templates.
- Mark which types require PPM, and optionally record the expected interval in months (informational).
- Create custom fields (text, number, date, checkbox, or dropdown), reorder them, edit them in a popup, scope each field to specific equipment types (or leave it visible on all equipment), and delete fields you no longer need.
- Define equipment statuses with a display colour and whether each status counts for dashboard reporting tiles.
- Turn the F-Gas compliance module on or off, choose which types of equipment get refrigerant fields (or turn on all equipment), set completion and leak-check behaviour, adjust leak-check interval months for different CO2e bands, review system default refrigerants, add your own refrigerant types with GWP, and open the F-Gas logbook template editor.
- Set master permissions so office staff and engineers can or cannot add equipment to jobs or create new equipment, before fine-tuning individuals in Staff Settings.
- Build asset registers and reports — choose columns (including checksheet test results and open defects), print as a Table or a Report with cards, cover, summary, sign-off and attached PDFs, and run them from Equipment, Reports, a customer or site.
Ask the assistant (Help & requests, or the chat on this page)
The assistant can read this page in words: your equipment types and the maintenance rule each one has, statuses and what they mean, custom fields and their choices, what the equipment pick lists and a site's equipment columns show, every asset register's columns, and your F-gas settings with the refrigerants in use. Ask it "why don't our engineers see the serial number when they pick a unit?" and it checks what the pick lists show before it answers.
With your yes it can change any setting here, add or rename types, statuses and refrigerants, add or change custom fields, and change an asset register: its name, its columns (equipment fields, checksheet answers, test results, open defects), which types and statuses it includes, its customer, whether customers see it in the portal, and the automatic report for completed jobs. Before deleting a register it shows you what goes with it.
These stay on this page: a register's printed layout (cover, summary, sign-off) and its attached PDFs, printing QR labels, moving equipment to another site, and the F-gas Show on dashboard switch.
Common Tasks
Set up types before you load lots of equipment or PPM
- Open Equipment Types.
- Enter a name and choose Add Type.
- Use Edit / Save to rename a type if your terminology changes — existing equipment and linked checksheets stay aligned when you rename from here.
- Only use Delete when nothing still uses that type; otherwise the system will refuse and list what still uses it — equipment, PPM checksheets, RAMS templates or certificate templates — so you can clear those links first.
Mark which types must have PPM cover
- Open Equipment Types.
- Tick Requires PPM on each type that should always sit on a maintenance schedule (for example passenger lifts, AHUs, fire alarms).
- Optionally enter PPM Interval (months) — for example
12for annual — as a reminder of your policy. This does not create schedules by itself; schedules are still set under PPM/Insp. - Changes save as soon as you change the tick or interval.
On the Equipment list, the filter PPM: Required, not covered then finds assets of those types that are not on any active schedule — useful after a bulk import or when a new type is introduced.
Add a custom question to every equipment record
- Open Custom Fields.
- Enter a field name and choose a field type, then Add Field.
- For a dropdown, open Edit on that row to add each allowed answer; renames update existing equipment using that answer; delete is blocked while any equipment still uses an option.
- Use the up and down arrows to change the order fields appear (custom fields cannot move above the fixed core block).
- By default a new field shows on All types (column Applies To says “All types”). To scope it, see the next task.
Change a custom field's type (for example a tick box into a Yes / No dropdown)
- Open Custom Fields and click Edit on the field.
- Pick the new Field Type and click Save Field Name/Type.
- If equipment already holds answers the new type can't show — a tick in a dropdown, words in a number field — a Saved answers list opens instead of saving: each saved answer, how many records have it, and a Becomes box filled in with a first guess (a tick becomes Yes; a box saved as unticked is left blank).
- Change any Becomes value you want, or leave it blank to clear that answer. For a dropdown, every answer you type becomes one of its options.
- Click Convert answers and save. The type and the answers change together — nothing changes until you click it.
Answers the new type can already show are kept as they are (anything at all, when the new type is text), and then no list appears.
Show a date as a year only, or a month and year
A Date field can be a full date (the normal date picker), a Month and year, or a Year only — for something you only know roughly, like a year of manufacture. Beside each date field, Date shows as sets it:
- Pick Year only (or Month and year).
- If records already have dates in that field, a message first says what will happen — for example "474 saved dates will be shortened (01/06/2002 becomes 2002)" — and OK does it. Nothing is ever made up: a date is only ever shortened.
- Dates that look like a year Excel turned into a 1905 date (typing 2002 into a date cell gives 24/06/1905) are listed; a second question asks whether to put them back to their real year.
From then on the box is a year box (or a month and a year), and the field reads 2002 or December 2000 everywhere — the record, lists and their filters, PDFs, checksheets, certificates, asset registers, the customer portal, both apps and imports (a spreadsheet column of years like 2002 imports as years). Going back to Full date is refused while any record only has a year or month — fill those in first. Engineers on an app version from before this change keep the year that is saved; update the app to edit it.
Scope a custom field to specific equipment types
- Open Custom Fields.
- On the row you want to scope, click Types in the Applies To column.
- A modal opens listing every equipment type. Tick the types this field should appear on (for example tick only AC and Refrigeration for a “Refrigerant Charge (kg)” field). Use Clear All to reset to “all types”.
- The summary line at the top of the modal updates as you tick (for example “Applies to: AC, Refrigeration” or “Applies to: All types” when nothing is ticked).
- Click Save. The row’s Applies To column now shows the scoped types (or “All types” if nothing was ticked).
- Engineers and the office only see the field on equipment whose Type matches one of the ticked types. On every other equipment type the field is hidden, but earlier answers are kept (not shown, not deleted).
- Changing an equipment’s Type later re-evaluates which custom fields apply — fields for the new type appear, fields no longer applicable disappear from the form (their earlier answers are kept).
- Deleting an equipment type clears it from the “Applies To” list of any field that referenced it. If that was the last type ticked, the field reverts to All types.
See the automatic "Last …" dates from your PPM checksheets
Under the Custom Equipment Fields table, Automatic fields — from your PPM checksheets lists one read-only date per PPM checksheet — Last followed by the checksheet's name (for example Last Water Meter Test) — plus Last PPM check (the last check of any checksheet). Each is the last time that check was completed on the asset; a check marked unable to complete or archived does not count. Nobody types these dates and nobody can change them, and renaming a checksheet renames its field. There is nothing to add, edit or delete here: a new checksheet brings its own field. Applies To follows the equipment types the checksheet is set up for.
The same panel also lists Next … due dates — Next PPM due (the asset's next PPM visit, the earliest across its schedules) and Next followed by a checksheet's name and due (for example Next Gas Safety due) for every checksheet a PPM schedule carries or that has a Usual frequency. Each is worked out for you: where a PPM schedule carries that checksheet for the asset, it is the schedule's visit that does (the same date the job is created from — fixed calendar, or counted from the last completion if the schedule row is ticked that way); where no schedule carries it, it is the last time the check was completed plus the checksheet's Usual frequency (set in the checksheet's builder). With neither, there is no date. The asset's page says where a date came from in small words under it. Nobody types these dates either.
Certificates too. A certificate that covers each piece of equipment (Setup → Certificates → "This certificate covers: each piece of equipment") adds the same pair to the panel: Last + the certificate's name (the latest certificate issued for the asset, dated the day of the original inspection — a reissue to fix a mistake does not move it) and Next + its name + due (shown when a PPM schedule carries the certificate or the certificate has a Usual frequency, set in the certificate designer's Template settings). Next due: the schedule's next visit that carries the certificate; otherwise that certificate's own next due date; otherwise its inspection day + the usual frequency. When a checksheet and a certificate share a name, the certificate's says "(certificate)". They tick on to the equipment record, the Equipment list, a site's Equipment tab and the customer portal like the checksheet dates; on templates they are print-only tags {{equipment_cert_last_<id>}} / {{equipment_cert_next_<id>}}. The certificate columns on the Equipment list show and export but do not sort or filter.
Show on the equipment record: tick the dates you want on each asset's own page and click Save. Nothing is ticked to start with, so the asset's page shows none until you choose. A ticked date appears as a locked Last PPM checks card on the asset's page in the office, on the engineers website and in both apps (the engineers' views only for people who can see equipment history). A checksheet that was never done on an asset shows Not done yet when it is set up for that asset's type.
Where else they show (each place has its own choice): columns you can pick on the Equipment list and in Site page equipment columns on this page, the customer portal (Customer Options), and read-only placeholders on job, work instruction, quote, PPM check and certificate templates. On a PPM check sheet you put one in with the advanced designer's automatic tools or the Simple builder's Equipment Details → Automatic — from your PPM checks ticks; the date then also shows, locked, while the check is being filled in (office, engineers website, both apps) — only on sheets that have it. On a check sheet the date is the last check before this visit (checks done on the same job do not count). If you keep a hand-typed "last service" or "last tested" field, these dates are the reliable replacement — they are not in the equipment pick lists.
Choose what the equipment pick lists show
When you pick a piece of equipment from a list — a quote task, a job, a ticket, a PPM, the apps — each option starts with its description. To make the right asset easy to spot, go to Equipment Setup → Custom Fields → What the equipment pick lists show, tick the details that should follow the description (your own fields such as a size or rating, or built-in ones like Make, Serial No or Location), put them in order with the arrows, and click Save pick lists. Up to 6. For example, ticking a Size field makes an option read Pump 2 · 50 mm instead of showing the Equipment Ref. A detail with nothing filled in is left out. Back to the standard pick lists returns every list to the text it showed before. The engineers app picks up a change at its next sync.
Standardise manufacturer spellings with a Make list
- Open Custom Fields and scroll to Standard lists for built-in fields.
- Choose the Make tab and pick the Equipment type the list is for (or leave All types).
- Add the spellings you want everyone to use (for example
Cla-Val,Watts Mustang,Bermad). Reorder with the arrows. - Choose Suggest (safe first step — autocomplete only) or List only (dropdown, with Other… for the unexpected), then Save mode.
- Click Preview under Link existing records. It lists every stored value that matches an entry once capitals, spaces and punctuation are ignored (for example "Cla Val" ×120 → Cla-Val), and separately the values that match nothing.
- Click Apply to re-spell the matching records. Values that matched nothing are left alone — add that spelling as an entry (or fix the typo on the records) and preview again.
Changing a mode never rewrites existing records by itself; only Link existing records → Apply does, and it shows you the counts first.
Colour-code operational state
- Open Statuses.
- Enter a name, pick a colour, tick Dashboard if this status should feed dashboard views, then Add Status.
- Set Uptime on each status: not counted, in service, or out of service. That classification drives Uptime columns on the Equipment list, the Equipment Uptime report, and the customer-portal uptime chart.
- Use Edit to adjust wording, colour, dashboard visibility, or uptime classification; Delete removes the status and clears it from equipment that used it.
Offer a parent's status change to its child assets
Under the statuses table, the Parent and child assets card has one tick box, Offer a parent's status change to its child assets (off until you tick it; it saves as you tick).
With it on, when someone changes the status of an asset that has child assets (for example a lock with its gates), they are asked whether to change the children too:
- The question lists every child with its current status. The children that were on the status the parent has just left are ticked — taking the lock Out of Service ticks the gates that were In Service with it; a gate somebody had set to Awaiting Parts is listed but not ticked. Anyone can tick or untick before choosing Change N, or choose Just this asset.
- A child already on the new status is shown greyed. If every child is already there, nothing is asked.
- The same question comes on the way back: bringing the lock back In Service ticks the gates that went out with it.
- Only a change to the parent asks. Changing a child never touches its parent or the other children.
- It asks wherever a person picks a status: the asset page, Equipment → Change Status on several assets at once (a child you ticked yourself is left out of the question), job and quote pages, the PPM checksheet, the engineers portal, the engineers app and the admin app. On a phone it is a plain yes / no for the ticked children, and in the engineers app it works with no signal.
- Each child changed gets its own History line and its own Uptime record, in the name of the person who answered — so a gate set Out of Service this way counts as down from that moment.
- Quote acceptance, the AI quoter, bulk upload, imports and deleting a status never ask and never change children.
- When a page saves and reloads (a job page's Save, the PPM checksheet), the question appears on the next page you open. It waits for 10 minutes.
Ask why an asset is out of service
Under Parent and child assets, the Why an asset is out of service card has one tick box, Ask why when an asset is set to a status that is not in service (off until you tick it; it saves as you tick).
With it on:
- Setting an asset to any status that is not marked In service in its Uptime setting — unmarked statuses included — opens a small Why is it …? box. The reason is required. It starts with the asset's newest open defect when there is one, and anyone can change the words.
- It asks wherever a person picks a status: the asset page, Equipment → Change Status (one reason for all the ticked assets), job and quote pages, the PPM checksheet, the engineers portal, the engineers app (it works with no signal) and the admin app. Cancel leaves the status as it was.
- The reason shows under the status at the top of the asset page (Why: …, with Edit to fix the words), and the asset page gains a Status history card: every status change with the date, who made it, the reason and how long it lasted. The Equipment Uptime report shows it under each asset's current status and adds a Why column to its CSV.
- Going back to an In service status clears the reason (the old one stays in the Status history). A reason never carries over onto a different status.
- When a parent's status is offered to its child assets, the children get the same reason.
- Quote acceptance and the AI quoter write their own words ("Quote Q-1042 accepted"). Bulk upload has an optional Status Reason column. Older engineers-app versions, imports and the external API are never stopped — a change from them simply has no reason ("No reason given" in Status history).
- It can print: job templates have
{{equipment_status_reason}}and a Status reason column on the equipment table, the site page's equipment table and asset registers can show a Status reason column, and automations on a piece of equipment's status changes can check the status and print the reason in an email. - Customers see nothing unless you tick Status reason in Customer Options → What your customers can see → Details customers see on an equipment record — then it shows beside the status on the asset's portal page (and, if you choose it, as a column on their equipment list). The box says "Your customer will see this" when that is on.
- Turning it off stops the asking and hides the reasons everywhere; nothing is deleted.
Build an Asset Register layout
- Open Asset Registers.
- Choose New Register, give it a name, add the columns you want, optionally Pin to customer, and optionally tick Customer can download from portal. Reorder columns with the arrows and type a Header override to print a column under your own heading.
- Save Register. Use Preview (first 10 rows) to check the rows, and Try the PDF to build the real PDF through the run window.
- Run it from Equipment → Export (uses the list's current filters), Reports → Asset Registers, the Reports tab on a customer or site, the customer record's Asset Register menu, or CSV / PDF on this list.
Add test results and open defects as columns
- Open defects — in the column picker, the Defects group offers Open defects (how many) and Open defect list. They count defects that are open, acknowledged, quoted or in progress.
- Test results — pick a checksheet from Test results from a checksheet…, then the answer you want: About the test (Date tested, Result (pass / fail), Tested by) or one of its Answers. For a reading in a table on the checksheet, choose First row, Last row or Every row. Click Add. The column shows a test result tag.
A test result comes from each asset's latest completed checksheet of that kind — or the latest inside the dates you choose when you run the register. The outcome is the worst answer (Fail, then Advisory, then Pass). A register with many columns prints in a smaller font.
Print a register as a report (cards, cover, summary, sign-off)
Under How it prints, choose:
- Table — one row per asset, the classic register. Best for long lists and spreadsheets.
- Report — one card per asset. Fields named "Group: Label" print as one box, ticked options as a list, and same-shaped groups (Pilot 1 / Pilot 2) as one table. Then set:
- Card title and Under the title (up to two lines), Group cards by (Site, Equipment type or No grouping), Page (Portrait / Landscape), Colour, Show the asset's photo and Show its status.
- Cover page — a title (the register name if blank), a subtitle, and optionally Your company name, address and logo.
- Summary page — an introduction, a table of up to 12 of your columns, the "5 assets at 3 sites" line, and Lowest, average and highest of number columns.
- Sign-off lines — one per line, for example Tested by and Date.
- The cover and summary can use the merge words {{customer}}, {{count}}, {{site_count}}, {{date}}, {{date_from}}, {{date_to}} and {{company}}. Any other word in double braces is refused when you save.
- Attached PDFs — spec sheets or calibration certificates added after the cards. Save the register first, then Attach a PDF (up to 5, 25 MB each). Remove takes one off; save the register to remove it for good.
A report can hold up to 400 assets; a bigger one is refused with a message to run it for one customer or site, or a shorter date range. A big report can take up to a minute to build.
Run a register (the run window)
Running a register opens a Run register window that only asks what the register needs: a Customer for a report that is not pinned to one (when you run it from a customer or site it is already set), and Tested between dates when the register has test-result columns (blank uses each asset's latest result). When there is nothing to ask, it builds straight away and the window just shows progress. Otherwise choose Download as PDF or CSV (spreadsheet) and click Download. If the register cannot be built, the reason shows in the window.
From a customer's or site's Reports tab you can also tick Save a copy on the customer (the button then reads Save & download). The copy is kept on their Reports tab, ready to open again or Add to invoice — which attaches it to an invoice for the same customer so the invoice email can include it. Saving a copy needs permission to edit customers; adding it to an invoice needs permission to edit invoices.
Run a report for one job
Every job has a Reports for this job section on its PPM/Certs/Compliance tab (it appears once you have at least one register that can hold that job's equipment). Run builds the report for the equipment on that job only, with the test results recorded on that job — there is no customer or date to choose. Tick Save a copy and it is kept on the job and on the customer's Reports tab; Add to invoice works the same as above. If none of the job's equipment is in the register, the window says so instead of printing an empty report.
Make a report automatically when a job is completed
In Asset Registers, click Automatic on a register, tick the job categories it is for, and choose whether to Add it to the job's invoice. From then on, shortly after a job in one of those categories is completed (and the engineer's app has finished sending its results), the report is made for that job, saved on the job and the customer, and — if ticked — added to the job's invoice. In the invoice email window a report added this way is already ticked to go with the invoice. Jobs completed before you switch it on are left alone, and each job gets its automatic report once (run it again from the job to save a fresh copy). While it is on, the register's name in the list carries a line such as Made automatically for Service, Testing jobs · added to the invoice. Untick every category to switch it off. A register report never replaces your job sheet — the job sheet PDF is unchanged.
Customers with portal access can download a shared register themselves, only for their own equipment, and can pick "tested between" dates on registers that read test results.
Enable F-Gas for HVAC-style work
- Open F-Gas / Refrigerant.
- Turn on Enable F-Gas Module, then Save F-Gas Settings.
- Choose either Enable F-Gas on ALL equipment or tick specific equipment types that should show refrigerant fields.
- Review Force Refrigerant Log on Jobs and Warn on Overdue Leak Checks so they match how strictly you want engineers and the office to be prompted.
- Adjust leak check interval months for the three CO2e bands if your policy differs from the on-screen UK-oriented defaults, then save again.
- Optionally open Edit F-Gas Logbook Template to brand and structure the downloadable logbook PDF.
Control who can add or create equipment on site
- Open Permissions.
- Tick the combinations you want for admin staff and engineers (add to job vs create new record).
- Save Permission Settings.
- In Staff Settings, grant the same capability per person; if a master switch here is off, the matching option stays unavailable for everyone.
When your customers' machines move between their sites (hire fleets, mobile plant)
On Permissions, under the admin switches, tick Our customers' equipment moves between their sites. It saves as you tick, and it is off unless you switch it on.
- When someone adds equipment to a job (the job page, or the job's Equipment tab in the Admin app), typing in the search also finds the same customer's machines at their other sites, under "At <customer>'s other sites", each showing where it is recorded. Type at least two letters of the name, reference or serial number.
- People with Move equipment to another site ticked on their staff profile see Move here and add. It shows what will happen first — the machine moves from the site it is recorded at to the job's site, its PPM schedule follows (as with Change Site on the Equipment page; it stays behind if the person cannot edit PPM schedules), any attached child assets move with it — and then Move and add moves it and puts it on the job. The equipment's History shows the site change and who made it.
- Everyone else sees where the machine is recorded and "Someone who can move equipment can bring it to …" — nothing moves.
- It only ever moves a machine within the same customer, to that job's own site, one at a time. If the job cannot take another machine (one machine per job, or a locked PPM job), it says so before moving anything.
- The engineers app does not do this yet.
Important Options
- Equipment Types drive dropdowns on equipment, PPM auto-linking by type, the optional F-Gas “select by type” list, and Requires PPM uncovered-asset detection — keep names stable where possible.
- Requires PPM does not create schedules. It only flags assets of that type with no active PPM schedule on the Equipment list (PPM: Required, not covered). Schedules are still created under PPM/Insp.
- PPM Interval (months) is informational guidance for your policy; it does not auto-schedule visits.
- Custom field type changes keep every saved answer the new type can show; anything it can't show is listed for you to convert or clear first (see Change a custom field's type). Changing away from dropdown removes its option list.
- Applies To on a custom field controls which equipment types show it. Empty selection = all types — if you have never used the Types picker, every custom field still shows on every equipment record.
- Scoping a field by type only hides it on non-matching equipment; previously entered values are preserved so nothing is lost if you re-add the type later.
- Custom fields feed AI asset registers — the AI assistant can include any custom field as a column when asked to generate an asset register or equipment report (for example “asset register for {customer} with pump makes and telemetry details”). Clear, descriptive field names (e.g. “Pump 1 Manufacturer” rather than “P1M”) make those registers read well.
- Custom fields can be placed on certificates as editable, linked fields (since 18/09/2026). In the certificate designer, the Equipment — editable palette lists every custom field here plus the standard Description / Ref / Make / Model / Serial / Location / Warranty Expiry. A linked field is pre-filled from the asset when the certificate opens and written back to the equipment record when the certificate is issued. The field's type, options and label here are what the certificate uses — rename or retype it and the next certificate follows. Applies To scoping is respected: a field scoped to certain types is hidden on certificates for other equipment. Type itself cannot be placed as a linked field. See
admin-portal/setup/certificates.md. - Statuses — Dashboard controls whether that status is highlighted in dashboard-oriented equipment views.
- Uptime classification is required before uptime percentages mean anything. Time in an unclassified status is excluded.
- F-Gas module off hides the detailed refrigerant panels; turning it on reveals scope (all equipment vs selected types), rules, thresholds, refrigerant library, and logbook template.
- Show F-Gas tile on Dashboard adds or removes leak-check summary tiles on the main admin dashboard when the module is enabled.
- Allow customers to view F-Gas data exposes refrigerant history and related downloads on the customer portal equipment view when your portal is used.
- Force Refrigerant Log on Jobs can block job completion if refrigerant-bearing equipment on the job has no gas log entry — use when you need a hard compliance gate.
- Track cylinders (under Force Rules) adds a cylinder number to every charge, top-up, recovery and decommission, a Cylinders register (what each cylinder holds and where it is) and a Disposals record of where recovered gas was sent — see the F-Gas page. Nothing changes for your engineers until it is ticked, and it can be unticked again without losing anything recorded. While it is ticked, Require a cylinder number on every recovery stops the web and app forms saving a recovery without one, with or without signal (an entry already saved on a phone — for example from an older app version — is never lost when it syncs, and the F-Gas log shows any still missing). If the box is greyed out with "Available after the next platform update", the feature is not switched on for the platform yet. With it ticked, engineers get a Cylinders tile on the app's home screen (the register, Add cylinder with its start quantity); Send for disposal from that tile needs Can record F-Gas disposals (app) on the engineer's staff record (Staff form → engineer permissions), off by default.
- System default refrigerant types are read-only references; add custom rows for blends or site-specific naming, and use Deactivate instead of delete when a type is already in use.
- Permissions are two-step: this page’s master switches plus per-user toggles in Staff Settings.
Common Mistakes
- Trying to delete an equipment type that still appears on live equipment, on a PPM checksheet, or on a certificate template that covers each piece of equipment of that type — remove or reassign those links first (for a certificate, untick the type under This certificate covers in the certificate designer), or rename instead of delete.
- Adding near-duplicate type names (“Lift” vs “LIFT”) which later make scheduling and F-Gas tick lists confusing.
- Expecting Custom Fields to include Description or Serial No — those are fixed; only Type’s pick-list is managed under Equipment Types. To make Make / Model / Location / Description a dropdown, use Standard lists for built-in fields instead of creating a duplicate custom field.
- Switching a field to List only and expecting old records to change — nothing already saved changes until you run Link existing records, and a typo ("Siemans") will not match a list entry ("Siemens"); fix those on the records, then link.
- Turning Other… off on a List-only field — an engineer who meets a manufacturer you haven't listed then has no way to record it correctly. Leave it on unless the list is genuinely complete.
- Ticking Requires PPM and expecting schedules to appear automatically — you still need to add the assets to a PPM contract/schedule under PPM/Insp.
- Adding a refrigerant or lift-specific field and forgetting to scope it via Types — engineers then see it on every asset (boilers, fire panels, etc.), creating noise on the equipment edit form. Pick the relevant types in the Applies To picker.
- Assuming a scoped field is gone after you change an equipment’s Type — the value is still stored, just hidden. Switch the Type back (or re-tick that type on the field) and the value re-appears.
- Turning F-Gas on for all equipment when only part of the fleet is refrigeration — engineers then see extra fields everywhere; prefer select by type unless the whole business is HVAC/refrigeration.
- Editing leak-check months without agreeing the values with your compliance process — intervals drive due and overdue behaviour.
- Assuming Permissions here are enough — individual staff and engineers still need matching ticks in Staff Settings.
- Forgetting to Save F-Gas Settings or Save Permission Settings after changing those sections.
- Expecting uptime columns or portal uptime charts before statuses are classified as in service / out of service.
Related Areas
- Sites and equipment editors — where types, custom fields, statuses, per-asset F-Gas flags, and the PPM Schedules panel are used day to day.
- Equipment list — PPM column and filters, including Required, not covered when types are marked here.
- PPM/Insp Checks Setup — checksheets can be linked to equipment types; types should exist before you rely on auto-linking.
- PPM Contracts — schedules pick checksheets; equipment type drives suggestions when auto-link is on; next visit dates feed each asset’s PPM status.
- Jobs and the engineer app — equipment selection, completion rules, and optional F-Gas logging.
- Staff Settings — per-user equipment permissions that respect the master switches on this page.
- Customer portal — optional visibility of F-Gas data on equipment when enabled here.
- Dashboard — optional F-Gas leak-check tiles when enabled.
- F-Gas logbook template — opened from this page to design the logbook PDF layout and branding.