What This Area Is For
The F-Gas menu opens the Refrigerant Log — a central place to review refrigerant-related activity across your account, support compliance reporting, and monitor leak-check due dates for equipment that is in scope for that tracking.
Day-to-day refrigerant entries (charges, top-ups, recoveries, leak checks, and similar) are usually captured on the job by engineers in the mobile app. This admin page is mainly for oversight, filtering, exports, and leak-check compliance, not for typing every field visit by hand.
If you do not see F-Gas in the main navigation, the refrigerant module is not enabled for your account. It is turned on from Equipment setup, on the F-Gas / Refrigerant tab.
What You'll See On This Page
Page header
- Title: Refrigerant Log
- Short subtitle explaining F-Gas compliance tracking across equipment
- Export CSV — downloads a spreadsheet of the currently filtered log rows (same columns as the on-screen table, suitable for auditors or spreadsheets)
Leak-check compliance summary (four tiles)
Four large clickable summary tiles appear near the top:
- Overdue — equipment whose next leak check date is before today
- Due within 30 days — next check due in the next 30 days
- Never checked — equipment that needs a first scheduled check (shown in the drill-down list as Never Checked (Requires Check))
- Compliant — next check due more than 30 days ahead
Each tile shows a count and Click to view. Selecting a tile opens a filtered equipment list below the tiles (not the main refrigerant log table). That list includes customer, site, refrigerant, charge, CO2 equivalent, last check, next due, and an action to open the equipment record.
When some leak checks could not be carried out, a chip Unable to test shows how many. Those units stay due.
Use Clear filter (or the link back to the full log) to leave the compliance drill-down and return to the normal log view.
Filter panel (main log)
Use Filter to apply criteria; use Clear to reset filters.
Visible filters for the main refrigerant log table:
- Customer
- Gas type (refrigerant type)
- Action — Initial Charge, Top Up, Recovery, Leak Check, Decommission
- Engineer
- Date from / Date to (calendar inputs; interpreted in your account timezone for display and filtering)
Totals bar (under the filters)
Summary chips for the filtered result set, including:
- how many entries are shown
- Charged and Recovered mass (kg)
- Net (charged minus recovered)
- count of Leak checks
Main results table
Columns typically include:
- Date (when the action was recorded)
- Customer, Site, Equipment (equipment name is a link to the equipment editor)
- Action (colour-coded). For Leak check, a small PASS / FAIL style badge may appear when a result was recorded
- Gas, Qty (kg), CO2e (t), Running (kg) (running charge after the entry)
- Engineer, Job (job number links to the job when a job was linked)
- Notes (truncated in the grid)
If there are many rows, the page may show a message that only the first 500 entries are listed and suggest narrowing with filters.
What You Can Do Here
- See who did what, on which equipment, for which customer/site, and on which job (when linked)
- Slice the log by customer, refrigerant, action type, engineer, and date range
- Export the current view to CSV for compliance files or analysis
- Use the compliance tiles to find equipment that is overdue, due soon, never checked, or compliant — then jump into equipment to update refrigerant details or plan work
- Open equipment or jobs directly from links in the table
Common Tasks
Find all refrigerant work for one customer
- Choose the Customer filter.
- Select Filter.
- Optionally narrow further by Date from / Date to or Action.
Review leak checks performed in a period
- Set Action to Leak check.
- Set Date from and Date to to your reporting window.
- Select Filter.
- Use Export CSV if you need a file.
See which equipment needs attention for leak checks
- Click Overdue, Due within 30 days, or Never checked on the summary tiles.
- Review the equipment list.
- Use View F-Gas (or the equipment name) to open the equipment record and work through scheduling or recording checks on site.
Prepare evidence for an audit
- Apply filters that match the audit scope (customer, date range, gas type, etc.).
- Select Export CSV.
- Keep the export with your other job and equipment evidence.
Cylinders and disposals (only when "Track cylinders" is ticked)
When your company ticks Track cylinders (Equipment setup → F-Gas / Refrigerant → Force Rules), each charge, top-up, recovery and decommission can record which cylinder the gas came from or went into, and the F-Gas pages gain three tabs: Log, Cylinders and Disposals. With the box unticked none of this appears.
- Log (this page) gains a Cylinder column, a Cylinder filter (type a number, or
noneto find recoveries with no cylinder number), and the Export CSV gains a Cylinder column at the end. A cylinder number in the column opens that cylinder; under a recovery whose cylinder has since been sent for disposal it adds → sent date to facility. People who can edit F-Gas records can tick entries — a bar appears at the bottom of the screen with a Cylinder number box, Set cylinder, Remove number and Cancel — or use the pencil next to an entry, to add, correct or clear a number afterwards. The original notes are kept and a line is added saying who changed it and when. Leak checks and corrections never carry a cylinder; ticked entries like that, or ones already on that number, are left as they were and the message says how many. - Cylinders lists every cylinder your team has named. A cylinder is added automatically the first time an engineer enters its number; you can also Add cylinder yourself. It shows the gas, whether it is a supply cylinder (gas taken from it) or a recovery cylinder (gas put into it), what it holds, its last movement and where it is. What it holds is worked out from the entries and disposals, so it needs a start quantity (a new recovery cylinder starts empty). Open a cylinder to see every movement, its disposals, and to Track as a tool — that creates a tool in Tools so it gets a holder (store, van or person), a QR label, test dates and certificates. Retire hides a cylinder from engineers without deleting its history.
- Disposals records where recovered gas went: the date, the route (Reclaim, Recycle, Destroy, Return to supplier, Other), the facility and its certificate or permit number, the waste carrier and registration, the consignment / transfer note number, and the quantity per cylinder. Select cylinders on the Cylinders tab and press Send for disposal, or start one from the Disposals tab. After saving you can attach the note. Deleting a disposal needs the word DELETE typed in.
- Chips above the filters point to anything worth tidying: recoveries with no cylinder number (opens the log filtered to them), cylinders that may hold more than one gas, and entries not yet linked to the register (both open Cylinders). To stop a recovery being saved without a number, tick Require a cylinder number on every recovery, which appears under Track cylinders once that is ticked — the web and app forms then refuse a recovery without one, with or without signal. An entry already saved on a phone is never lost when it syncs (one from an older app version can arrive without a number), so the chip still catches those.
- The F-Gas logbook template can show a Cylinder column and a Recovery and disposal section (both off until ticked in the logbook template editor). The job sheet and PPM F-Gas tables can add a Cylinder column in the template builder.
- The three tabs sit on their own row under the page title on all three pages.
- A new cylinder's start quantity: when someone types a cylinder number the register has not seen, the entry form (web and app) asks What is in it now? — what was in the cylinder before that entry (a full new cylinder is its fill weight). It is optional; it is applied only when the register row is created, so a figure the office has already entered is never overwritten, and if two people name the same new cylinder the first start quantity stands.
- From the app: engineers with the Cylinders tile can add a cylinder (with its start quantity) and, when their staff record has Can record F-Gas disposals (app), record a disposal at the facility with a photo of the completed transfer note. Those disposals appear on Disposals with a phone icon and "Recorded by name (engineer, from the app)"; the photo arrives under Paperwork on the sync after the record. Editing or deleting a disposal stays an office action.
A cylinder number is not a legal requirement in itself; it is the simplest way to show which cylinder recovered gas went into and where that cylinder went.
Important Options
These are configured outside this page but change what engineers must do and what appears elsewhere:
- Equipment setup → F-Gas / Refrigerant — enables the module, refrigerant types, which equipment types are in scope, and options such as forcing refrigerant logging or leak checks on the app for qualifying equipment.
- Dashboard — optional F-Gas tiles (e.g. overdue / due soon) can be added when your team enables dashboard visibility for F-Gas from that same setup area.
Common Mistakes
- Expecting to enter every log line here — most entries originate from engineers on jobs (and equipment). This page is for visibility and export, not the primary data-entry screen.
- Confusing the compliance list with the log — clicking a compliance tile shows equipment due-status, not the chronological refrigerant log. Use Clear filter to get back to the full log table.
- Missing the F-Gas menu — the menu item is hidden until the module is enabled in Equipment setup.
- Very wide date ranges — the table is capped at 500 rows; tighten filters if you need a complete picture in one view.
Related Areas
- Equipment — refrigerant type, charge, CO2 equivalent, last/next leak check; section labelled for F-Gas on the equipment editor.
- Jobs — where engineers attach refrigerant activity to live work; job numbers in the log link back here.
- Engineers app — where compliant teams usually record charges, top-ups, recoveries, and leak checks against equipment on the job.
- Equipment setup → F-Gas / Refrigerant — module switch, refrigerant catalogue, equipment-type scope, and enforcement options for the app.