What This Area Is For
The Cylinders tile shows your company's refrigerant cylinder register on your phone: every cylinder that has been named on an F-Gas entry or added by the office, what each one holds, and who has it. From it you can add a cylinder the moment it is delivered (with what is in it) and send cylinders for disposal when recovered gas goes to a reclaimer — recording the facility, the carrier, the transfer note number and a photo of the completed note, there and then.
It works offline. Everything you add or record saves on the phone first and reaches the office when you next sync.
You only see the tile when your company has ticked Track cylinders (Equipment Setup → F-Gas). Send for disposal also needs the permission Can record F-Gas disposals (app) on your staff record; without it you can still see the register and add cylinders.
What You'll See
- A search box — type part of a cylinder number.
- Mine — only the cylinders you have used on this phone, plus any the office has allocated to you (when a cylinder is tracked as a tool and you hold it, it counts as yours before you have used it).
- Each cylinder: its number, the gas, Supply cylinder (gas is taken from it) or Recovery cylinder (gas is put into it), Holds … (or Contents not set when nobody has said what was in it), and Held by … when the office tracks it as a tool. Not synced yet means you added it on this phone and it has not reached the office.
- Add cylinder and, with the permission, Send for disposal.
- Under the list, Disposals recorded on this phone: date, where the gas went, the cylinders and quantities, Sent to the office or Waiting to sync, and the photo's state (Photo queued, Photo uploaded, or Photo waiting to upload — will retry).
Adding a cylinder
For a delivery nobody has used yet — a new 9 kg cylinder arrives on site, say.
- Add cylinder.
- Type the number from the label or collar, or Scan it.
- Kind: Supply (gas taken from it) or Recovery (gas put into it).
- Gas — pick the refrigerant.
- What is in it now? — optional, but this is what makes Holds … right from day one. A full new cylinder is its fill weight. Leave it blank if you do not know; the office can set it later.
- Capacity and Notes are optional. Add to register.
If the number is already on the register the app says so and changes nothing. A number that is spelt differently (spaces, dashes, "Cylinder" in front) is still the same cylinder.
You can also add a cylinder without coming here: on a job's F-Gas entry, a cylinder number that is not on the list asks the same What is in it now? question before you save.
Sending cylinders for disposal
- Send for disposal, tick the cylinders that went, Continue.
- The quantity sent from each cylinder starts at what it holds — change it if the weighed figure was different.
- Date sent, and Where the gas went: Reclaim, Recycle, Destroy, Return to supplier (a supply cylinder going back part-full) or Other.
- The facility (name, address, certificate or permit number), the waste carrier and its registration number, the consignment / transfer note number, and any notes.
- Photo of the completed transfer note — Take photo or Choose from Gallery, up to five. Tap a photo to remove it.
- Record disposal.
The gas leaves each cylinder's contents straight away on your phone. The record goes to the office on the next sync and appears on the office's Disposals tab marked as recorded by you; the photo uploads once the record has arrived (so a photo can sit at Photo queued for one sync). Only the office can change or delete a disposal afterwards.
Common Questions
- The tile is not there. Your company has not ticked Track cylinders, or your phone has not synced since they did. Pull down on the home screen to sync.
- I can see the register but not Send for disposal. Ask your office for Can record F-Gas disposals (app) on your staff record.
- Holds … is wrong. The figure comes from the start quantity plus every entry and disposal. If a cylinder says Contents not set, the office can enter its start quantity on the Cylinders tab; your own corrections go through the F-Gas entries themselves.
- I recorded a disposal offline. It shows Waiting to sync until you have signal, then Sent to the office. The photo follows on the sync after that.
- Two engineers added the same new cylinder. It is one cylinder on the office's register; the first start quantity entered is kept.